The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and
Jered R Wells1, Olav Christianson2, Dustin A Gress3,4
1Clinical Imaging Physicians Group, Duke Health, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.
Abstract:
CMS has adopted a new CT quality measure seeking to discourage excessive radiation dose while preserving image quality. The measure score is expressed as the percentage of qualifying studies that exceed predetermined thresholds, indicating inadequate image quality (based on image noise) or excessive radiation dose. The measure has been incorporated into the major CMS quality-based payment programs, impacting hospitals and clinician payments; measure reporting began in January 2025. After measure development, practitioners identified a spectrum of concerns and impediments, prompting the American Association of Physicists in Medicine to convene a multidisciplinary expert panel to provide further guidance. The panel identified 20 issues and ambiguities in the measure specifications, stemming from metrology concerns, unconventional terminology, and inconsistencies with practice standards or norms; these issues relate to themes of applicability, categories and metrics, informatics, performance expectations, and meta considerations. In this article, the panel presents these issues and ambiguities with associated recommendations to promote the measure's intentions. These recommendations include greater data access (e.g., to the measure's source data and to reporting elements for audit support) and a more holistic treatment of image quality. The panel ultimately urges a shift toward open-source, open-access, consensus-based, and community-owned strategies to ensure CT quality and safety.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...