Related Experiment Video
Updated: May 25, 2025

Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Photon-Counting Detector CT Iodine Maps Versus SPECT/CT: Advancing Lung Perfusion Imaging in Chronic Thromboembolic
Bjarne Kerber1, Martin Hüllner, Alexander Maurer
1Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., T.Fl., T.Fr., S.F.); Department of Nuclear Medicine, University Hospital Zurich, University Zurich, Zurich, Switzerland (M.H., A.M.); Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, Maastricht, the Netherlands (T.Fl.); and Clinic of Pulmonology, University Hospital Zurich, Zurich, Switzerland (S.U., M.L.).
Objectives:
The aim of this study was to compare the accuracy of photon-counting detector computed tomography (PCD-CT) iodine maps of the lung parenchyma with perfusion scintigraphy for detection and extent estimation of pulmonary perfusion defects.
Materials And Methods:
This institutional review board-approved retrospective study included 26 subjects (11 male, aged 57.2 ± 15.8 years; 15 female, aged 55.2 ± 15.7 years) who underwent clinically indicated PCD-CT and perfusion SPECT/CT to assess for chronic thromboembolic pulmonary hypertension (CTEPH). Two blinded radiologists used CT iodine maps and corresponding sharp-kernel CT reconstructions in lung window to evaluate presence and extent of lobar perfusion defects and detect patients with CTEPH (or CTEPH overlap with other causes of PH). Accordingly, 2 blinded nuclear medicine physicians/radiologists evaluated perfusion SPECT/CT scans. The clinical diagnosis was reviewed in an interdisciplinary clinical setting. Quantitative analyses were calculated for both modalities. Perfusion defect estimation was compared with right heart catheter measurements.
Results:
Of the 26 subjects included, 10 were diagnosed with CTEPH or CTEPH overlap, 12 were diagnosed with PH associated with other pathologic mechanisms, 3 had no PH, and 1 had previous acute pulmonary embolism, which resolved. Radiation dose was greatly reduced for PCD-CT compared with SPECT/CT (1.19 [±0.33] mSv; 6.34 [±1.68] mSv, respectively, P < 0.001). Both PCD-CT readers (R1, R2) showed a trend toward higher accuracy, sensitivity, and specificity for CTEPH diagnosis compared with the scintigraphy consensus (SC) (accuracy: R1 0.85, R2 0.88, SC 0.73; sensitivity: R1 0.90, R2 0.90, SC 0.80; specificity: R1 0.81, R2 0.88, SC 0.69), although there was no significant difference observed ( P > 0.688). There was good to excellent agreement between both PCD-CT readers for perfusion defect estimation. Moderate intermodality agreement was observed for CTEPH diagnosis certainty and perfusion defect estimation. The quantitative evaluation showed strong to excellent correlation between PCD-CT and SPECT/CT relative perfusion. There was a significant moderate correlation between PCD-CT perfusion defect estimations and mean pulmonary artery pressure (R1: r = 0.49, P = 0.020; R2: r = 0.49, P = 0.021), pulmonary vascular resistance (R1: r = 0.60, P = 0.003; R2: r = 0.52, P = 0.013), and cardiac index (R1: r = -0.45, P = 0.042).
Conclusions:
PCD-CT iodine maps allow for accurate CTEPH detection and are comparable to perfusion SPECT/CT with good quantitative correlation, but only moderate qualitative agreement, at greatly reduced radiation dose. Furthermore, visual PCD-CT perfusion defect extent was associated with prognostic right heart catheter measurements.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...