Assessing the impact of uncertainty in a VMAT plan for H&N cancer considering patient setup error (PSE)
Arvind Kumar1, Kiran Sharma2, C P Bhatt3
1Graphic Era Deemed to Be University, Dehradun, Uttarakhand, 248002, India; All India Institute of Medical Sciences (AIIMS), Rishikesh, Uttarakhand, 249203, India.
Abstract:
In radiotherapy, accurate radiation dose delivery is critical, despite the uncertainties that can cause discrepancies between the prescribed and administered doses. This study examines the influence of uncertainties caused by patient positioning errors on dose accuracy and evaluates the potential consequences if these errors remain uncorrected. The investigation involves 670 treatment plans, including 10 clinically implemented plans and 660 with artificially induced uncertainties. These plans target patients undergoing volumetric arc therapy (VMAT) for various head & neck cancers using the Halcyon™ medical linear accelerator. Two scenarios are analyzed: one reflecting actual patient positioning shifts and another involving deliberate displacements ranging from 1 to 10 mm to assess the impact of uncertainty in a VMAT plan. Dosimetric validation is performed using EPID and the Octavius 4D phantom to introduce and assess the impact of these uncertainties. Results indicate that target coverage falls below the acceptable V95% threshold along the (X+, X-), (Y+, Y-), and (Z+, Z-) axes, when positioning errors exceed 5 mm. Additionally, both parotid glands are significantly affected by positioning uncertainties. Patient-specific quality assurance (PSQA) assessments confirm that positioning errors substantially affect the accuracy of dose delivery. To minimize uncertainties, strict adherence to recommended QA, clinical guidelines, imaging protocols, and other SOPs is crucial in clinical practice. Independent dosimetric audits are essential for evaluating the accuracy of dose delivery in treatment.
More Related Videos
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Uncertainty: Overview
Propagation of Uncertainty from Random Error
Propagation of Uncertainty from Systematic Error
Uncertainty: Confidence Intervals
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...