Related Experiment Video
Updated: May 24, 2025

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Two-photon optical Ramsey-Doppler spectroscopy of positronium and muonium
Evans Javary1, Edward Thorpe-Woods1, Irene Cortinovis1
1Institute for Particle Physics and Astrophysics, ETH, Zurich, 8093 Switzerland.
Abstract:
Positronium and muonium, as purely leptonic atoms without internal structure, provide ideal systems for high-precision tests of quantum electrodynamics (QED) and measurements of fundamental constants. However, the high velocities of these lightweight atoms complicate precision spectroscopy, particularly in the 1 S-2 S transition, due to transit time broadening and second-order Doppler shifts. To overcome these challenges, we propose a novel method combining two-photon Ramsey spectroscopy with a technique to correct the second-order Doppler shifts on an atom-by-atom basis. Additionally, this approach suppresses systematic effects of the AC Stark shift to a negligible level compared to the target precision. Simulations predict that for both positronium and muonium, this method could improve the measurement precision of the 1 S-2 S transition by more than two orders of magnitude compared to the current state of the art. This approach opens up new avenues for rigorous bound state QED tests and searches for physics beyond the standard model.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
UV–Vis Spectroscopy: Molecular Electronic Transitions
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...

