Related Experiment Video
Updated: May 24, 2025

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Selenium(VI) Removal by Continuous Flow-Through Iron Electrocoagulation: Effects of Operating Conditions and
Xicheng He1, Elaine D Flynn2, Jeffrey G Catalano2
1Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, Missouri 63130, United States.
Abstract:
Selenium (Se) contamination is widespread, and Se(VI) removal from water is particularly challenging. This study evaluated Se(VI) removal using iron electrocoagulation (EC) in a flow-through reactor under various water chemistry and operating conditions. Effective Se(VI) removal (>98% from 1000 μg/L Se) was achieved under anoxic conditions with an iron dose as low as 30 mg/L and an EC reactor residence time as short as 11 s that was followed by a 1-h settling period. The removal remained stable over an extended operating time (24 h) and involved the generation of reactive Fe(II)/Fe(III) solids (green rust and magnetite). Oxic conditions were less effective for Se removal because of limited Se adsorption at the elevated pH of the effluent. The immobilized Se in the solids was in a reduced form (-II or 0), but about 70% of Se was oxidized after air exposure. Despite the reduced forms of Se being oxidized, very little Se was released from the solids and the toxicity characteristic leaching procedure indicated that EC-generated solids can be classified as nonhazardous. This study highlights the potential of flow-through iron EC to produce iron-containing adsorbents and reductants that can be tailored for Se(VI) and other oxyanion removal. It also offers practical insights into designing effective treatment systems and ensuring the safe disposal of EC-generated residual solids in real-world applications.
More Related Videos
08:34A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration
Published on: December 5, 2019
06:52Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron OxyHydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
Related Concept Videos
Precipitation and Co-precipitation
Electrodeposition
Electrodeposition can...
Extraction: Advanced Methods
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Coagulation
Formation of Complex Ions