Related Experiment Video
Updated: May 24, 2025

Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Parametric Cyclic Voltammetric Analysis of an Electrochemical Aptasensor for Staphylococcus aureus Iron-Regulated
Shokoufeh Soleimani1, Tracy Ann Bruce-Tagoe2, Najeeb Ullah2
1Department of Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee, Knoxville, TN 37996, USA.
Abstract:
Rapid and reliable detection of pathogens requires precise and optimized analytical techniques to address challenges in food safety and public health. This study focuses on the parametric characterization of an electrochemical aptasensor for Staphylococcus aureus (S. aureus) iron-regulated surface determinant protein A (IsdA) using cyclic voltammetry (CV) analysis, which offers a robust method for evaluating electrode modifications and electrochemical responses. Key parameters were optimized to ensure maximum sensitivity, including an aptamer concentration of 5 μM, an incubation time of 4 h, a potential range from -0.1 to 0.9 V, and a scan rate of 0.05 V/s. The aptasensor achieved stability and peak performance at pH 7.5 and 25 °C. These conditions were critical for detecting the IsdA protein as a biomarker of S. aureus. The aptasensor applicability was demonstrated by successfully detecting S. aureus in food samples such as milk and apple juice with high specificity and reliability. Zeta potential measurements confirmed the layer-by-layer charge dynamics of the AuNPs-aptamer-IsdA system. This work emphasizes the importance of CV in understanding the performance of the electrochemical sensor, and supports the aptasensor as a practical, sensitive, and portable tool for addressing critical gaps in foodborne pathogen detection.
More Related Videos
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrogravimetric Analysis: Overview
To test the completeness of the...