Related Experiment Video
Updated: May 23, 2025

An Alternative Approach for Sample Preparation with Low Cell Number for TEM Analysis
Published on: October 12, 2016
Enhancing specimen preparation for transmission electron microscopy: Trypan Blue staining and low-melting-point agar
Noriyuki Ishii1, Yoshito Koja2, Keiichi Noguchi3
1Cellular and Molecular Biotechnology Research Institute, Department of Life Science and Biotechnology, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central-6, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan; Electron Microscopy Facility, Open Research Facilities Station, Open Research Platform Unit, Tsukuba Innovation Arena (TIA) Central Office, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central-6, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan; The United Graduate School of Agricultural Science, Gifu University, 1-1 Yanagido, Gifu, Gifu 501-1193, Japan; Department of Physics, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo, Hamamatsu, Shizuoka 431-3192, Japan.
Abstract:
The observation of ultrathin sections of cells and other specimens using transmission electron microscopy (TEM) is a standard technique in many biological research laboratories. Cells are typically collected, dehydrated through an ascending series of alcohols, and embedded in resin blocks before being sectioned with an ultramicrotome. This multi-step process can be time consuming and error prone. To address these challenges, we introduced modifications to improve sample visualization while avoiding hazardous substances like osmium tetroxide and epoxy resins (e.g., Araldite), which are increasingly regulated internationally. Specifically, we stained cells with Trypan Blue and used low melting point agar, facilitating visual identification of target areas and enabling precise embedding. As a result, visual tracking of samples prior to embedding for TEM was improved, preventing the cutting of empty blocks and ensuring efficient preparation of ultrathin sections.
More Related Videos
09:58Preparation of Prokaryotic and Eukaryotic Organisms Using Chemical Drying for Morphological Analysis in Scanning Electron Microscopy SEM
Published on: January 7, 2019
08:04Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography
Published on: March 12, 2017
Related Concept Videos
Preparation of Samples for Electron Microscopy
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...