Related Experiment Video
Updated: May 23, 2025

Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Exploring the predictive value of carotid Doppler ultrasound and clinical features for spinal anesthesia-induced
Esmée C de Boer1,2, Joris van Houte3, Catarina Dinis Fernandes4
1Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands. e.c.d.boer@tue.nl.
Background:
The induction of spinal anesthesia is often followed by hypotension, which has been associated with post-operative end-organ damage. A timely prediction of spinal anesthesia-induced hypotension (SAIH) paired with appropriate interventions may reduce the risk of adverse outcomes. This study investigated the value of carotid Doppler ultrasound measurements and clinical variables, both individually and combined, to predict SAIH.
Methods:
Adult patients who were scheduled for elective surgery under spinal anesthesia were included. Carotid ultrasound imaging and baseline vital sign measurements were performed pre-operatively, well in advance of the induction of spinal anesthesia. The occurrence of hypotension was observed for ten minutes after the induction of spinal anesthesia. Logistic regression models studied linear relationships within the derived set of ultrasound and clinical features, and support vector machine models evaluated nonlinear relationships.
Results:
A total of 40 patients were included, and 45% of them developed SAIH. The logistic regression models performed better than the support vector machine models. The best-performing logistic regression model combined carotid ultrasound and clinical features and had a sensitivity of 75 [73-81]%, specificity of 75 [71-81]%, AUROC of 0.81 [0.75-0.95], positive predictive value of 75 [65-81]%, negative predictive value of 75 [71-88]% and F1 score of 0.75 [0.71-0.76]. The key features that were shown to predict SAIH were baseline mean arterial pressure, fasting time, ASA class, and weight.
Conclusions:
Combining carotid Doppler ultrasound measurements and clinical variables can predict the occurrence of SAIH.
Trial Registration:
The study was retrospectively registered at clinicaltrials.gov (NCT06711289) on 2 December 2024.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Local Anesthetics: Clinical Application as Spinal Anesthesia
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Pre-Procedural Guidelines for Assessing Blood Pressure