Related Experiment Video
Updated: May 23, 2025

Non-invasive Skeletal Muscle Quantification in Small Animals Using Micro-computed Tomography
Published on: November 8, 2024
Open-Source Image Analysis Software Yields Reproducible CT Measures of Longissimus Muscle Area and Density in Sheep
Jeryl Jones1, Anna Brewer2, Susan Duckett1
1Department of Animal and Veterinary Sciences, Clemson University, Clemson, South Carolina, USA.
Abstract:
Longissimus muscles (LM) in sheep are important for animal scientists who study meat quality and translational researchers who study thoracolumbar spinal disease. Computed tomography (CT) is an established technique for characterizing paraspinal muscles in sheep; however, studies reporting reproducibility of CT measures using open-source software are lacking. The objectives of this prospective pilot study were to develop a standardized protocol for measuring LM area and density in sheep using CT and to determine the reproducibility for measurements. Thoracolumbar CT images were acquired for four sheep at five time points each as part of another study. Six observers applied a standardized CT image analysis protocol to record triplicate transverse area (cm2) and water phantom-corrected mean density (Hounsfield units, HU) values for the left and right LM. Average coefficients of variation (CVs) for 4 of 6 observers were good to excellent (<10%) for all variables. Average CVs did not differ among observers for 3 of 4 variables (ANOVA, p > .05).