Related Experiment Video
Updated: Jul 14, 2026

05:34
Author Spotlight: Advancing Pathogen Diagnostics with Standardized LAMP
Published on: September 8, 2023
667
Rapid Detection of Aeromonas veronii Using GGDEF Gene-Based Colorimetric Loop-Mediated Isothermal Amplification
Tien Tien Vicky Lau1, Suat Moi Puah1, Kek Heng Chua1
1Department of Biomedical Science, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
Journal of Fish Diseases
|March 11, 2025
Summary
A new colorimetric loop-mediated isothermal amplification (LAMP) assay rapidly detects Aeromonas veronii, a key fish pathogen. This 30-minute test offers high specificity and sensitivity, crucial for aquaculture health.
Area of Science:
- Microbiology
- Aquatic Animal Health
- Molecular Diagnostics
Background:
- Aeromonas veronii is a significant fish pathogen impacting global aquaculture.
- Rapid and accurate detection methods are vital to mitigate economic losses.
- Existing detection methods can be time-consuming or require specialized equipment.
Purpose of the Study:
- To develop a rapid, colorimetric loop-mediated isothermal amplification (LAMP) assay for detecting Aeromonas veronii.
- To evaluate the specificity, sensitivity, and accuracy of the developed LAMP assay.
- To compare the performance of the LAMP assay with conventional PCR.
Main Methods:
- A colorimetric LAMP assay was designed targeting a GGDEF domain-containing diguanylate cyclase gene in A. veronii.
- The assay was optimized for reaction time (30 min) and temperature (65°C).
- Specificity was tested against common fish pathogens, and sensitivity was determined using purified plasmid and genomic DNA.
Main Results:
- The LAMP assay provided a clear color change (pink to yellow) within 30 minutes at 65°C.
- 100% specificity was observed against other fish pathogens.
- The limit of detection (LOD) was 500 pg/μL for plasmid DNA and 1.72 × 10^5 cfu/mL for genomic DNA.
- The assay showed high agreement with conventional PCR (94.7% accuracy, 0.888 Cohen's kappa).
- LOD in spiked water samples was 1.72 × 10^5 cfu/mL.
Conclusions:
- The developed colorimetric LAMP assay is a rapid, specific, and sensitive tool for detecting Aeromonas veronii.
- This assay offers a valuable alternative to conventional PCR for routine diagnostics in aquaculture.
- It facilitates timely interventions to control A. veronii outbreaks and minimize economic impact.
Keywords:
Aeromonas veroniicolorimetric loop‐mediated isothermal amplification (LAMP)fish pathogenrapid detectionsensitivityspecificity
