Influence of Applied Pressure and Thickness Variation on the Bond Strength Between 3Y-TZP Zirconia and Self-Adhesive
Paulo Pinto1,2,3, Óscar Carvalho1,2,3, Rita Ferreira1,2,3
1Center for Micro-Electro Mechanical Systems (CMEMS-UMinho), University of Minho, Guimarães, Portugal.
Abstract:
This study evaluated the influence of applied pressure on the shear bond strength (SBS) between commercial 3Y-TZP zirconia and self-adhesive resin cement. Five test groups were created, each subjected to different applied pressures: 195.15, 97.47, 48.74, 9.75, and 0.20 kPa. A piston-type shear device was used to assess the effect of these pressures on cement layer thickness and SBS. The results demonstrated that the highest applied pressure (195.15 kPa) produced the thinnest cement layers (36.60 ± 1.67 μm) and the highest SBS values (58.8 ± 1.6 MPa), whereas the lower applied pressure (0.20 kPa) resulted in the thickest cement layers (73.20 ± 1.64 μm) and significantly lower SBS (30.8 ± 2.0 MPa). Regression analysis confirmed a strong correlation (R2 = 0.82, p < 0.05) between cement thickness and SBS, indicating that cement thickness is a critical factor influencing adhesion. These findings highlight the importance of controlling applied pressure during cementation to optimize bonding performance. Standardizing pressure application through calibrated pressure devices may improve the durability of zirconia-based restorations and minimize variability during the cementation process.
More Related Videos
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
08:45Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Related Concept Videos
Bonding and Strength of Aggregate
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...