Related Experiment Video
Updated: May 22, 2025

A Method to Test the Efficacy of Handwashing for the Removal of Emerging Infectious Pathogens
Published on: June 7, 2017
Temperature Changes of NaOCl after Irrigation Using Passive Ultrasonic Irrigation, Easy Clean, and XP-Endo Finisher:
Geraldo Edson Freitas Athayde de Moraes1, Daniel Guimarães Pedro Rocha2, Carlos Eduardo Fontana2
1Conservative surgery Department, Collage of Oral and Dental Surgery, Misr University for Science and Technology (MUST), Giza, Egypt.
Abstract:
The aim of this study was to evaluate the temperature changes of sodium hypochlorite (NaOCl) after the use of different activation techniques: passive ultrasonic irrigation (PUI), XP-Endo Finisher (XP), and Easy Clean (EC).Thirty patients were selected for this randomized crossover study and each patient received root canal treatment in maxillary incisor. Each tooth was subjected to three activation techniques in a random order in the final irrigation of the treatment. All irrigation was performed using a 2.5% NaOCl solution, with the solution's temperature stabilized at 21°C (baseline) in the syringe. No agitation was used as a control before the use of the devices. After each activation technique, the intracanal temperature was measured using a K-type thermocouple. Statistical analyses were performed using Kruskal-Wallis and Dunn tests.Temperatures remain in the range of 21.0 to 21.2°C at baseline and were higher in the control (29.5-34.1°C), PUI (29.9-34.2°C), EC (29.8-35.6°C), and XP (29.9-34.7°C) groups. The temperature average of the baseline period was inferior to those observed in all groups; moreover, despite of temperature changes among the control and all experimental groups no difference between them were identified.The temperature increase caused by activation with PUI, EC, and XP was similar and did not exceed the levels observed when no agitation was performed.
More Related Videos
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Electrolysis
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...