Enhancing Radiation Shielding Efficiency of Nigella sativa Eumelanin Polymer Through Heavy Metals Doping
Mohammad Marashdeh1, Nawal Madkhali1
1Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13318, Saudi Arabia.
Abstract:
Gamma radiation shielding is necessary for many applications; nevertheless, lead creates environmental risks. Eumelanin, a natural polymer, is a viable alternative, although its effectiveness is limited to lower gamma-ray energy. This research looks at how doping the herbal eumelanin polymer (Nigella sativa) with heavy metals including iron (Fe), copper (Cu), and zinc (Zn) affects its gamma radiation shielding characteristics. The inclusion of these metals considerably increases the linear attenuation coefficient (μ) and mass attenuation coefficient (μ) of eumelanin, especially at lower photon energies where the photoelectric effect is prominent. The μ value of pure eumelanin is 0.193 cm-1 at 59.5 keV. It goes up to 0.309 cm-1, 0.420 cm-1, and 0.393 cm-1 when Fe, Cu, and Zn are added, in that order. Similarly, the mass attenuation coefficients increase from 0.153 cm2/g for pure eumelanin to 0.230, 0.316, and 0.302 cm2/g for the Fe-, Cu-, and Zn-doped samples. At intermediate and higher energies (661.7 keV-to-1332.5 keV), where Compton scattering is the main interaction, differences in attenuation coefficients between samples are not as noticeable, which means that metal additions have less of an effect. The mean free path (MFP) and radiation protection efficiency (RPE) also show these behaviors. For example, at 59.5 keV the MFP drops from 5.172 cm for pure eumelanin to 3.244 cm for Mel-Fe, 2.385 cm for Mel-Cu, and 2.540 cm for Mel-Zn. RPE values also go up a lot at low energies. For example, at 59.5 keV Cu-doped eumelanin has the highest RPE of 34.251%, while pure eumelanin only has an RPE of 17.581%. However, at higher energies the RPE values for all samples converge, suggesting a more consistent performance. These findings suggest that doping eumelanin with Fe, Cu, and Zn is particularly effective for enhancing gamma-ray shielding at low energies, with copper (Cu) providing the most significant improvement overall, making these composites suitable for applications requiring enhanced radiation protection at lower gamma-ray energies.
More Related Videos
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Biological Effects of Radiation
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Absorption of Radiation
Radiation: Applications
The average...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay: