Related Experiment Video
Updated: May 22, 2025

In vivo Measurement of Knee Extensor Muscle Function in Mice
Published on: March 4, 2021
A straightforward method to record the peak torque value when using a cantilever spring mechanical torque limiting
Chandur Pk Wadhwani1, Kwok Hung Chung2
1Private practice (Prosthodontics), Bellevue, Wash; and Science Director, Foundation for Oral Rehabilitation, Luzern, Switzerland.
This study introduces a simple, inexpensive device to improve torque limiting devices for dental implants. The new device accurately records peak torque and eliminates viewing angle parallax, enhancing measurement reliability.
Area of Science:
- Biomaterials and Implantology
- Mechanical Engineering
- Dental Instrumentation
Background:
- Implant cantilever beam torque limiting devices are crucial for precise dental implant procedures.
- Current devices face limitations in accurately recording peak torque application.
- Viewing angle parallax in existing devices compromises measurement accuracy.
Purpose of the Study:
- To develop a simple and inexpensive device to overcome the limitations of current torque limiting devices.
- To enhance the accuracy of peak torque recording in implant procedures.
- To eliminate viewing angle parallax issues in torque measurement.
Main Methods:
- A novel device was designed and integrated between the measurement reader arms of the torque instrument.
- The device was tested for its ability to record peak torque values.
- The impact of the device on viewing angle parallax was evaluated.
Main Results:
- The developed device successfully records the peak torque applied during implant procedures.
- The device effectively resolves the issue of viewing angle parallax.
- The solution is characterized as simple, inexpensive, and effective.
Conclusions:
- The novel device offers a significant improvement over existing torque limiting devices for dental implants.
- Accurate peak torque recording and elimination of parallax enhance procedural safety and predictability.
- This innovation provides a cost-effective solution for improving dental implant instrumentation.
More Related Videos
08:58Atomic Force Microscopy Cantilever-Based Nanoindentation: Mechanical Property Measurements at the Nanoscale in Air and Fluid
Published on: December 2, 2022
11:25A Millimeter Scale Flexural Testing System for Measuring the Mechanical Properties of Marine Sponge Spicules
Published on: October 11, 2017
Related Concept Videos
Net Torque Calculations
Screw: Problem Solving
To evaluate the...
Circular Shafts - Elastoplastic Materials
As torque on the...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Residual Stresses in Circular Shafts
Angle of Twist: Problem Solving