Quantification of nine phthalate esters in a plastic sample using relative molar sensitivities obtained by gas
Yuko Kitamaki1, Satoko Otsuka1, Toshihide Ihara1
1National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan.
Abstract:
Gas chromatography combined with mass spectrometry (GC-MS) has been commonly used in various analytical fields because of its high selectivity and sensitivity; however, for reliable quantification, this method requires a calibrant for each target. By contrast, GC combined with post-column reaction flame ionization detection (-r-FID) can quantify all organic compounds from a single reference on the basis of their number of carbons, which is attributed to the conversion of organic compounds into methane after separation; however, it is not suitable for matrix extracts because GC-r-FID detects all carbon-containing compounds injected into the GC. In this study, we developed a novel method for the reliable quantification of target analytes by combining GC/MS and GC-r-FID. The relative molar sensitivity (RMS) of each target analyte was obtained beforehand from the responses of GC-MS and GC-r-FID using calibration solutions, and each target analyte in matrix-extracts was quantified from the GC-MS responses and RMS. Because the reliability of RMS is important in this method, we examined the reliability of RMS as the first step. We then applied the developed method and verified it by quantifying nine phthalate esters in a matrix-type certified reference material (NMIJ CRM 8152-a, phthalate esters in polyvinyl chloride resin). The analytical results obtained using this method were comparable to those obtained using the conventional method (internal standard method) and those certified or information values. Since RMS can be obtained using common reagents, this method should be suitable for the reliable quantification of target analytes even when corresponding reference materials are not available.
More Related Videos
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...