Related Experiment Video
Updated: Jul 15, 2026

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
DCAN: Dynamic Channel Attention Network for Multi-Scale Distortion Correction
Jianhua Zhang1, Saijie Peng1, Jingjing Liu1
1Shanghai Key Laboratory of Chips and Systems for Intelligent Connected Vehicle, School of Microelectronics, Shanghai University, Shanghai 200444, China.
Abstract:
Image distortion correction is a fundamental yet challenging task in image restoration, especially in scenarios with complex distortions and fine details. Existing methods often rely on fixed-scale feature extraction, which struggles to capture multi-scale distortions. This limitation results in difficulties in achieving a balance between global structural consistency and local detail preservation on distorted images with varying levels of complexity, resulting in suboptimal restoration quality for highly complex distortions. To address these challenges, this paper proposes a dynamic channel attention network (DCAN) for multi-scale distortion correction. Firstly, DCAN employs a multi-scale design and utilizes the optical flow network for distortion feature extraction, effectively balancing global structural consistency and local detail preservation under varying levels of distortion. Secondly, we present the channel attention and fusion selective module (CAFSM), which dynamically recalibrates feature importance across multi-scale distortions. By embedding CAFSM into the upsampling stage, the network enhances its ability to refine local features while preserving global structural integrity. Moreover, to further improve detail preservation and structural consistency, a comprehensive loss function is designed, incorporating structural similarity loss (SSIM Loss) to balance local and global optimization. Experimental results on the widely used Places2 dataset demonstrate that DCAN achieves state-of-the-art performance, with an average improvement of 1.55 dB in PSNR and 0.06 in SSIM compared with existing methods.
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
Distance Corrections
Uniform Depth Channel Flow
Uniform Depth Channel Flow: Problem Solving

