Concordance between Centiloid Quantification and Visual Interpretation of Amyloid PET Scans across the Alzheimer
Mohammad Khalafi1, Seyed Hani Hojjati1, Xiuyuan H Wang1
1From the Department of Radiology (M.K., S.H.H., X.H.W., L.Z., Y.L., T.A.B., Q.R.R., E.B.T., S.P., L.G., N.S.F., M.J.d.L., G.C.C.), Brain Health Imaging Institute, Weill Cornell Medicine, New York, New York.
Background And Purpose:
Accurate identification of cerebral β-amyloid (Aβ) accumulation is crucial for diagnosing Alzheimer disease (AD) and determining eligibility for anti-Aβ therapies. The Centiloid (CL) scale has emerged as a standardized method to harmonize Aβ PET quantification across different tracers and sites. We aimed to evaluate the concordance between CL quantification and visual interpretation in a cohort of cognitively impaired (CI) and unimpaired (CU) participants who underwent Aβ PET.
Materials And Methods:
Two hundred twenty-one participants (mean age 69 ± 12.3 years) were prospectively enrolled in AD studies and underwent 247 Aβ PET scans, including 157 with [11C]-Pittsburgh compound B (PiB) and 90 with [18F]-florbetaben (FBB). Standardized uptake value ratios (SUVRs) were converted to the CL scale following Global Alzheimer's Association Interactive Network guidelines. Percent agreement and κ statistics were used to evaluate the concordance between CL thresholds and visual interpretation in determining Aβ positivity.
Results:
The highest concordance rate for the whole cohort was 93% by using a CL cutoff of 18 (κ coefficient 0.84). Using FBB, the concordance rate was highest by using a CL cutoff of 24 (97%), whereas the concordance rate for PiB peaked at 94% at a CL cutoff of 18. Concordance was higher in negative rather than positive Aβ PET cases, 98% versus 90%. Concordance was slightly higher in CI participants compared with CU (96% versus 93%). Disagreement commonly occurred when focal areas of Aβ positivity were identified on visual interpretation but did not meet the threshold globally by CL quantification.
Conclusions:
Global CL quantification of Aβ PET scans is highly concordant with visual interpretation. Combining both methods may provide a more complete assessment of the extent of Aβ deposition in the brain.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET