High-efficiency [18F]fluoride pre-concentration using a laser-micromachined anion-exchange micro-cartridge
Antonio Arleques Gomes1, Arian Pérez Nario2, André Luis Lapolli2
1Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN-SP), São Paulo, SP, CEP 05508-000, Brazil. antonio.gomes@usp.br.
Background:
The use of radiopharmaceuticals labelled with fluorine-18 in non-invasive imaging, particularly in Positron Emission Tomography (PET), increased significantly during the last decade. However, traditional nucleophilic fluorination synthesis methods in most cases require azeotropic drying steps, leading to loss of activity and increased synthesis time. Microfluidic devices offer improvements with shorter reaction times, higher elution efficiency, and reduced reagent quantities.
Results:
We developed a novel micro-cartridge for [18F]fluoride trapping and elution, etched in borosilicate optical glass (BK7) using ultrashort laser pulse machining. The micro-cartridge has a bead volume of 17 µL and a maximum capacity of 8.5 mg for anion exchange resin. The micro-cartridge, without the need for QMA preconditioning, exhibited an overall trapping efficiency and recovery efficiency (RE) of (94.09 ± 0.12)% using an activity exceeding 123 GBq of [18F]fluoride. This RE was obtained using 100 µL of a standard solution of anhydrous acetonitrile with Kryptofix 2.2.2, containing only 5 µL of water and 5.4 µmol of K2CO3 for [18F]fluoride elution. This solution was employed directly in the radiosynthesis of [18F]fluoromisonidazole ([18F]FMISO), resulting in a 100% radiochemical conversion (RCC) to THP-protected [18F]FMISO within 10 min at 110 °C.
Conclusions:
The developed micro-cartridge provides a novel tool for integrating microfluidic chips into conventional cassettes, facilitating more efficient radiopharmaceutical preparation.
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...
High-Performance Liquid Chromatography: Elution Process
Catalytically Perfect Enzymes
Most enzymes...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...