Signatures of Charged Droplets from ESI: A Statistical Analysis of Non-summed Mass Spectra Compared to APCI
Chris Heintz1, Hendrik Kersten1, Thorsten Benter1
1Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaussstraße 20, 42119 Wuppertal, Germany.
Abstract:
Electrospray ionization (ESI) is the most widely used technique for the ionization of liquid samples, for example, from liquid chromatography (LC) coupled to mass spectrometry. Recent experiments demonstrate the penetration of charged droplets or at least large clusters into the high-vacuum region of different ESI mass spectrometers. Using a Bruker micrOTOF equipped with a standard Bruker Apollo ESI source, we demonstrated that time-of-flight (TOF) MS can detect signatures of these droplets by analyzing the statistics of individual TOF spectra, resulting from a single orthogonal acceleration (oa) stage pulse. A custom experimental setup allows additional online monitoring of the ion current in the oa-stage by coupling an oscilloscope to an auxiliary secondary electron multiplier (SEM). The results obtained with ESI are compared to mass spectra recorded under similar conditions using atmospheric pressure chemical ionization (APCI). Our findings reveal that the observation of droplet signatures is unique to the ESI process, with their frequency and intensity strongly determined by the ion source settings. We also report that the majority of the individual spectra obtained do not contain ion signals. The observed intensity in the summed spectra stems from a few very intense spectra, which result from single droplet fragment bursts. In contrast, APCI provides an almost continuous and stable ion current, without intense signal bursts characteristic for ESI. Additional optical monitoring strongly suggests that these signatures are not a result of spray instability, but are common even for undisturbed, continuous spray operation. The variation of ion source parameters shows that specific capillary voltages, nebulizer pressures, and dry gas flows lead to an increase in the frequency of droplet occurrence. Since these parameters are fundamental and frequently altered in analytical measurements, the results reported in this contribution underscore the significance of understanding droplet dynamics in ESI-MS and provide insights regarding droplets affecting the ESI signal intensity recorded in analytical runs.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences