Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Wrist-Worn and Arm-Worn Wearables for Monitoring Heart Rate During Sedentary and Light-to-Vigorous Physical
Theresa Schweizer1, Rahel Gilgen-Ammann1
1Department of Monitoring and Evaluation, Swiss Federal Institute of Sport Magglingen SFISM, Hauptstrasse 247, Magglingen, 2532, Switzerland.
Background:
Heart rate (HR) is a vital physiological parameter, serving as an indicator of homeostasis and a key metric for monitoring cardiovascular health and physiological responses. Wearable devices using photoplethysmography (PPG) technology provide noninvasive HR monitoring in real-life settings, but their performance may vary due to factors such as wearing position, blood flow, motion, and device updates. Therefore, ongoing validation of their accuracy and reliability across different activities is essential.
Objectives:
This study aimed to assess the accuracy and reliability of the HR measurement from the PPG-based Polar Verity Sense and the Polar Vantage V2 devices across a range of physical activities and intensities as well as wearing positions (ie, upper arm, forearm, and both wrists).
Methods:
Sixteen healthy participants were recruited to participate in this study protocol, which involved 9 activities of varying intensities, ranging from lying down to high-intensity interval training, each repeated twice. The HR measurements from the Verity Sense and Vantage V2 were compared with the criterion measure Polar H10 electrocardiogram (ECG) chest strap. The data were processed to eliminate artifacts and outliers. Accuracy and reliability were assessed using multiple statistical methods, including systematic bias (mean of differences), mean absolute error (MAE) and mean absolute percentage error (MAPE), Pearson product moment correlation coefficient (r), Lin concordance correlation coefficient (CCC), and within-subject coefficient of variation (WSCV).
Results:
All 16 participants (female=7; male=9; mean 27.4, SD 5.8 years) completed the study. The Verity Sense, worn on the upper arm, demonstrated excellent accuracy across most activities, with a systematic bias of -0.05 bpm, MAE of 1.43 bpm, MAPE of 1.35%, r=1.00, and CCC=1.00. It also demonstrated high reliability across all activities with a WSCV of 2.57% and no significant differences between the 2 sessions. The wrist-worn Vantage V2 demonstrated moderate accuracy with a slight overestimation compared with the ECG and considerable variation in accuracy depending on the activity. For the nondominant wrist, it demonstrated a systematic bias of 2.56 bpm, MAE of 6.41 bpm, MAPE 6.82%, r=0.93, and CCC=0.92. Reliability varied considerably, ranging from a WSCV of 3.64% during postexercise sitting to 23.03% during lying down.
Conclusions:
The Verity Sense was found to be highly accurate and reliable, outperforming many other wearable HR devices and establishing itself as a strong alternative to ECG-based chest straps, especially when worn on the upper arm. The Vantage V2 was found to have moderate accuracy, with performance highly dependent on activity type and intensity. While it exhibited greater variability and limitations at lower HR, it performed better at higher intensities and outperformed several wrist-worn devices from previous research, particularly during vigorous activities. These findings highlight the importance of device selection and wearing position to ensure the highest possible accuracy in the intended context.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Holter Monitor: 24-Hour Monitoring