Small signal synchronization stability of hybrid synchronization based DC voltage control with different inner
1Electric Power Research Institute of Guangdong Power Grid Co., Ltd., Guangzhou, 510600, China. prongc@yeah.net.
Abstract:
Hybrid synchronization based DC voltage control (HS-DVC) with phase locked loop is claimed to perform well in strong grid compared with traditional grid forming based DC control (GFM-DVC) for renewable energy sources (RESs). However, the small signal synchronization stability of HS-DVC with different inner control loops is less analyzed in the previous literatures. To fill this gap, the small signal synchronization stability of HS-DVC with different inner control loops is investigated and the stability enhancement is unveiled in this article. A closed loop model focusing on the synchronization loop is proposed, i.e., the synchronization unit is seen as the controller, and the inner control loop, reactive power loop and power stage are seen as the plant. With the proposed model, synchronization stability of HS-DVC under three different inner control loops, cascaded voltage current loop, single voltage loop and voltage magnitude phase loop (referred to as type i, ii, and iii) can be evaluated in one frame work. Four insights about HS-DVC proposed in this article are revealed. The larger inertia constant deteriorates the system stability of traditional GFM-DVC and HS-DVC is stable with relatively large inertia constant. Compared with HS-DVC with only AC and DC voltage synchronization in the previous work, the HS-DVC in this work with inclusion of active power synchronization has a better stability. Compared with type i and type ii based inner control loops, the type iii based inner control loop is easier to be stable. Unlike the DC voltage equivalent RESs, DC current equivalent RESs introduce right half plane poles in the plant and the stability becomes worse in weak grid with DC current equivalent RESs. Electromagnetic transient (EMT) simulations with Simulink are performed out to verify the analysis.
More Related Videos
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Fast Decoupled and DC Powerflow
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Generator Voltage Control