Performance of Sewer Concretes with Calcium Sulpho-Aluminate Cement and Portland Cement Blends: Field and Laboratory
Alice Titus Bakera1,2, Amr Aboulela3, Mark G Alexander1
1Department of Civil Engineering, University of Cape Town, Rondebosch 7701, South Africa.
Abstract:
This paper discusses the performance of calcium sulpho-aluminate (CSA) cement and a Sulphate-Resisting Portland Cement (SRPC) with a fly ash (FA) additive (i.e., a SRPC + FA binder system) in a 'live' sewer environment; it deepens the understanding of their deterioration mechanisms by using a laboratory test for simulated sewer conditions. It also studies the role of an iron-based additive ('Hard-Cem®', HC) in improving the performance of SRPC + FA concrete under a biogenic acid attack. The performance of 0.4 w/b concrete specimens of the three binders (CSA, SRPC + FA, and SRPC + FA + HC) with calcite aggregates in sewer exposure was assessed by visual observation, measurements of mass and thickness changes, and microstructural analysis for approximately 25 months. The laboratory test, i.e., the Biogenic Acid Concrete (BAC) test, was used to study the deterioration mechanisms of these binders in terms of leaching solution pH and standardised cumulative leached calcium and aluminium. The results indicate that CSA concrete had improved performance in the sewer environment, showing no mass loss and only about one-third of thickness lost in the SRPC + FA concrete over a 25-month exposure period in the sewer environment. The BAC test results complemented the field observations. The iron-based additive in sewer concrete slightly reduced mass loss, likely due to its better resistance to abrasion and erosion, but not due to any chemical influence, since it does not participate in hydration or dissolution reactions. The findings imply that CSA cement may represent a suitable alternative binder for concrete sewer construction. They also suggest that a surface hardener has limited benefits, except when it is under abrasive conditions. Further investigation is required, especially since CSA contains high amounts of sulphate, the effect of which is not well understood.
More Related Videos
05:36Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Types of Cement II
Pozzolans
Fly ash is...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Hydration of Cement
Testing Water Quality
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...