Optical coherence tomography for the qualitative analysis of thyroid tissue images: Feasibility, features, and
Yun Shao1, Qianru Xu2, Cuixia Feng3
1Department of Pathology, Fifth Medical Center of Chinese PLA General Hospital, Beijing, China.
Abstract:
The most important steps in thyroid surgery include distinguishing benign from malignant lesions and identifying the parathyroid glands. Optical coherence tomography (OCT) provides technical support for intraoperative guidance owing to its real-time, three-dimensional imaging capability. Benign and malignant diagnoses can be confirmed with intraoperative frozen sections; however, current approaches are time-consuming and labor-intensive and do not allow comprehensive, nondestructive tissue assessments. This study aimed to explore the use of OCT for imaging the thyroid tissue by verifying its clinical feasibility and qualitatively analyzing the OCT imaging characteristics of pathological thyroid glands. A customized swept-source OCT (SS-OCT) system was used to collect OCT data corresponding to the pathologies of 61 freshly excised tissue blocks containing either benign or malignant lesions from 45 patients. The OCT images were highly consistent with the H&E histological images, verifying the feasibility of OCT in producing suitable images for analysis. The OCT-derived characteristics of the thyroid tissue were as follows: normal thyroid follicles presented with regularly arranged honeycomb structures; follicular nodular disease (FND) was characterized by heterogeneous nodules composed of follicles of different sizes, with multiple nodules also differing in size and consisting of varied reticular structures and a focally solid appearance; lymphocyte aggregation led to a gray‒black appearance in Hashimoto's thyroiditis tumors; and papillary thyroid carcinoma lesions were characterized by a heterogeneous texture and a low penetration depth. These results demonstrate the imaging capabilities of OCT for thyroid tissue with different pathological conditions and its broad prospects for clinical application.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography