Related Experiment Video
Updated: May 11, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 30, 2011
Evaluation of Transcutaneous Non-Invasive Blood Gas Analysis for Monitoring Gas Exchange in Pediatric Cardiac
Gaurav Pandey1,2, Salman Pervaiz Butt1, Arshad Ghori1
1Heart Vascular and Thoracic Institute, Cleveland Clinic, Abu Dhabi, United Arab Emirates.
Introduction:
Pediatric cardiac surgery patients need close post-extubation monitoring for ventilation. Non-invasive transcutaneous partial pressure of oxygen (TcPO2) and transcutaneous partial pressure of carbon dioxide (TcPCO2) offer continuous insights and in improving care.
Objective:
To investigate the correlation of transcutaneous blood gases (TcPO2, TcPCO2) with arterial blood gases i.e. arterial partial pressure of oxygen (PaO2) and arterial partial pressure of carbon dioxide (PaCO2).
Methods:
We conducted a study on 30 pediatric post-cardiac surgery patients (four months to three years old) who were extubated and exhibited stable hemodynamics (inotropic score ≤ 5), normal sinus rhythm, and no respiratory or heart failure signs. Continuous transcutaneous and intermittent arterial blood gas monitoring started one hour after extubation, with recordings every 30 minutes for four hours. A single observer conducted probe calibration and data recording to minimize variability, while analysis of 240 paired samples included correlation coefficient, linear regression, Bland-Altman analysis, and Mountain plot.
Results:
The r-value between PaCO2 and TcPCO2 was 0.95, r2-value of 0.9060 (P<0.001). Bland-Altman showed a bias of 2.579, and 95% limits of agreement were -6.4 to 1.3. The r-value between PaO2 and TcPO2 was 0.8942, r2-value of 0.7996 (P<0.001); bias of 20.171 and 95% limit of agreement of -0.5 to 40.9. The Mountain plot revealed a median of 2.57 for PaCO2 vs. TcPCO2 and 20.17 for PaO2 vs. TcPO2.
Conclusion:
Transcutaneous carbon dioxide values are interchangeable with arterial PaCO2 in our population study, acting as a surrogate in postoperative pediatric cardiac surgery. Confirmation with arterial blood gases is needed if discrepancies occur.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Endotracheal Tube Extubation
Procedure