Using Cornell Product to Predict Echocardiographic Response of Left Bundle Branch Area Pacing
Selda Murat1, Gurbet Özge Mert1, Fatih Enes Durmaz2
1Department of Cardiology, Eskişehir Osmangazi University, Eskişehir, Türkiye.
Objective:
Cardiac resynchronization therapy with left bundle branch area pacing (LBBAP) is a novel resynchronization technique that serves as an alternative to biventricular pacing. This study investigated the predictive value of electrocardiographic Cornell Product (CP) in identifying super-responders to LBBAP among heart failure patients with left bundle branch block (LBBB).
Method:
This retrospective study included 32 patients who underwent LBBAP, had a left ventricular ejection fraction (LVEF) ≤ 35%, were in sinus rhythm with LBBB and a QRS duration ≥ 150 ms, and had been receiving optimal medical therapy for at least three months. CP was calculated from baseline 12-lead electrocardiography (ECG) using the following formula: CP (mm x ms) = [(RaVL + SV3) x QRS duration]. Super-response was defined as an increase of at least 15% in LVEF six months after the procedure. Patients were classified as super-responders or non-super-responders, and their clinical, electrocardiographic, and echocardiographic parameters were compared.
Results:
Among the 32 patients, 53% (n = 17) were identified as super-responders. The mean age of participants was 65.2 +- 9.9 years, and 46.9% were female. Based on baseline 12-lead ECG, CP was significantly lower in the super-responder group (3788.4 [3222.4-4569.6] mm*ms vs. 5174.0 [4516.4-5296.0] mm*ms, P = 0.044). Additionally, multivariate analysis revealed that systolic pulmonary artery pressure (odds ratio [OR]: 1.08; P = 0.041) and CP (OR: 1.01; P = 0.036) were independent predictors of super-response to LBBAP.
Conclusion:
CP, a simple and readily applicable electrocardiographic parameter, can serve as a predictor of which patients will benefit from LBBAP.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...