Related Experiment Video
Updated: Feb 11, 2026

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
MIP-based electrochemical sensor with machine learning for accurate ZIKV detection in protein- and glucose-rich urine
Wannisa Sukjee1, Pichai Sirisangsawang2, Chutima Thepparit3
1Department of Chemistry, Faculty of Science, Kasetsart University, Bangkok, 10900, Thailand; Center for Advanced Studies in Nanotechnology for Chemical, Food, and Agricultural Industries, Kasetsart University Institute for Advanced Studies, Kasetsart University, Bangkok, 10900, Thailand; Advanced Porous Materials for One Health Integrations (APM Unit), Special Research Incubator Unit, Kasetsart University, Chatuchak, Bangkok, 10900, Thailand.
Abstract:
Nowadays, a multitude of biosensors are being developed worldwide. However, a significant challenge arises when these biosensors are tested in real sample environments, as many of them fail to perform as expected. This can lead to ambiguous results and raise concerns about their reliability. In many cases, further data analysis is required to enhance the clarity and meaningfulness of the outputs. In this study, we investigated the acrylamide-methacrylic acid-methyl methacrylate-vinylpyrrolidone copolymer for fabrication of molecularly imprinted polymers, aimed at developing electrochemical sensors for the direct detection Zika virus in urine. Here, Zika virus detection by the biosensor in three types of urine possibly found in clinical samples including normal, high glucose (glucose >540 mg/dL) and high protein urines (protein >100 mg/dL). The results show that the signal obtained from normal urine increased with virus concentration, while it decreased in urine with high glucose or high protein level. Support vector machine was introduced to unify two opposite trends and resolve ambiguity of the data. It was able to sift through the noise and extract valuable information, thereby improving the reliability and achieved 91 % accuracy in detecting the analyte spiked into real patient samples.
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Filtration and Urine Formation
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Machines
A free-body diagram of the...
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...

