Simultaneous analysis of various anticancer drugs by supercritical fluid chromatography-mass spectrometry. Part I:
Nathalie Nguyen1, Davy Guillarme2, Serge Rudaz2
1Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, School of Pharmaceutical Sciences, CMU - Rue Michel-Servet 1, Geneva, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Pharmacy, Geneva University Hospitals (HUG), Rue Gabrielle Perret-Gentil 4, Geneva 1205, Switzerland.
Abstract:
This work presents a generic SFC-MS method for the simultaneous analysis of 22 anticancer drugs (fluorouracil, busulfan, cyclophosphamide, cytarabine, dacarbazine, daunorubicin, docetaxel, doxorubicin, epirubicin, etoposide, gemcitabine, idarubicin, ifosfamide, irinotecan, methotrexate, paclitaxel, pemetrexed, raltitrexed, topotecan, treosulfan, vinblastine, vincristine). The separation conditions were optimized by screening nine stationary phases (2-picolylamine, bare hybrid silica, 2-ethylpyridine, fluoro-phenyl, octadecyl, diethylamine, diol, 1-aminoanthracene, zwitterionic modification), evaluating additives effects (2-5 % water, 20-50 mM ammonium formate, 0-1 mM ammonium fluoride), and adjusting the organic modifier composition (methanol, ethanol, isopropanol, acetonitrile). The optimized SFC-MS method successfully analyzed 22 anticancer drugs, along with 5 additional challenging compounds (azacitidine, mitomycin, cisplatin, oxaliplatin, carboplatin), in 12 min, using a diol column (100 × 3 mm, 1.7 µm) and a gradient of 2-100 % methanol containing 2 % water and 50 mM ammonium formate. To overcome overpressure generated by high organic solvent content, a backpressure gradient (110-150 bar) and a flow rate gradient (0.6-1.5 mL/min) were applied. The diol column was selected as the most promising based on five predefined chromatographic criteria. Additives with 5 % water or ammonium fluoride were excluded due to overpressure and signal loss, respectively. Increasing ammonium formate concentration improved peak symmetry by 29 %. For the organic modifier, pure methanol was chosen since ternary mixtures led to system overpressure without improving separation. Comparison with the LC-MS method using real samples confirmed the potential applicability of the SFC method, as the same trace compounds were detected with comparable concentrations. Sensitivity optimization and method validation will be discussed separately in a later paper.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...