Development of a control method for micro-gyroscopes using self-excitation and frequency measurement techniques
Xin Liu1,2, Peng Sun1,2, Yinyu Liu1,2
1Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Abstract:
Micro-Hemispherical Resonator Gyroscopes (MHRGs) serve as essential components in inertial navigation systems. This research introduces a novel digital closed-loop control system for the application of the force-to-rebalance mode. The proposed methodology utilizes a self-excitation technique to initiate oscillation. First, the amplitude of the oscillatory signal detected by the Analog-to-Digital Converter (ADC) is calculated. This amplitude is subsequently amplified by a predetermined factor and multiplied with the ADC-detected signal. The resultant product serves as the input for the digital-to-analog converter, facilitating the generation of a drive signal for the MRHG. Upon the oscillation amplitude attaining a specified threshold, the control system transitions the drive control to the Direct Digital Synthesis (DDS) module. Concurrently, we employ a high-frequency clock to measure the frequency of the ADC sampling signal. The measured frequency is then used to establish a reference frequency range for the Proportional-Integral-Derivative (PID) controller, with the aim of expediting the convergence speed. Finally, a PID block based on the standard IEEE-754 floating-point format is implemented to perform fine-grained adjustment of the DDS frequency control word. Experimental results demonstrate that the amplitude control shows a variation of ±1% with respect to the reference value. For MHRGs with different Q factors and resonant frequencies, the phase error between the drive and detection signals is maintained within ±0.5°.
More Related Videos
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
15:25Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
Related Concept Videos
Gyroscope
Gyroscope: Precession
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
Microbial Growth Measurement: Direct Methods
Microbial Growth Measurement: Indirect Methods