Related Experiment Video
Updated: Jun 14, 2026

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Fast and Robust Single-Shot Cine Cardiac MRI Using Deep Learning Super-Resolution Reconstruction
Taraneh Aziz-Safaie1, Leon M Bischoff, Christoph Katemann
1Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (T.A.-S., L.M.B., D.Kr., N.M., L.D.B., T.D., C.C.P., D.Kü., J.A.L., A.I.); Quantitative Imaging Laboratory Bonn, Bonn, Germany (T.A.-S., L.M.B., D.Kr., N.M., L.D.B., D.Kü., J.A.L., A.I.); Philips GmbH Market DACH, Hamburg, Germany (C.K., O.M.W.); and Philips MR Clinical Science, Best, the Netherlands (J.M.P.).
Deep learning reconstruction of single-shot (SSH) cine cardiac MRI significantly reduces scan times while maintaining diagnostic image quality. This advanced technique offers superior results in patients with arrhythmias or poor breath-holding capabilities.
Area of Science:
- Cardiovascular Imaging
- Artificial Intelligence in Medicine
- Medical Image Reconstruction
Background:
- Cardiac MRI is crucial for diagnosing cardiovascular diseases.
- Standard multishot balanced steady-state free precession (bSSFP) cine sequences are time-consuming and sensitive to patient motion.
- Deep learning (DL) offers potential for accelerated image acquisition and improved quality.
Purpose of the Study:
- To compare the diagnostic quality of DL-reconstructed single-shot (SSH) cine cardiac MRI with standard multishot cine.
- To evaluate the impact of DL on scan time and image quality metrics.
- To assess performance in specific patient subgroups, including those with arrhythmias.
Main Methods:
- Prospective study comparing DL-SSH cine with standard cine in patients undergoing cardiac MRI.
- Acquisition at 1.5 Tesla using breath-holding and ECG-gating.
- Subjective (readers' assessment) and objective (edge definition, SNR, CNR) image quality evaluation.
- Assessment of functional left ventricular (LV) parameters.
Main Results:
- DL-SSH cine acquisition time was 65% shorter than standard cine (92s vs 265s).
- DL-SSH cine demonstrated comparable or superior subjective image quality, particularly in endocardial edge definition.
- No significant differences in objective metrics like apparent signal-to-noise ratio (aSNR).
- Strong correlation for LV functional parameters (ejection fraction r=0.95).
- Improved image quality ratings for DL-SSH cine in patients with arrhythmia or unreliable breath-holding.
Conclusions:
- DL reconstruction of SSH cine cardiac MRI accelerates acquisition while achieving non-inferior diagnostic quality.
- DL-SSH cine offers superior diagnostic quality in challenging patient populations, such as those with arrhythmias.
- This technology holds promise for more efficient and effective cardiac MRI examinations.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
