Related Experiment Video
Updated: Jul 14, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
A systematic approach for estimating ICRU Report 95 operational quantities for personnel monitoring using a 3-element
Munir S Pathan1,2, S M Pradhan1, T Palani Selvam1,2
1Radiological Physics & Advisory Division, Health, Safety & Environment Group, Bhabha Atomic Research Centre, Mumbai, India.
Abstract:
The introduction of International Commission on Radiation Units and Measurements (ICRU) Report 95 marks a revision of operational quantities (OQs) for individual monitoring due to external radiation exposures. This revision has a major impact, particularly in low photon energy range (20-100 keV), where the conversion coefficients of existing [(Hp(10)] and new [(Hp)] OQs for whole body dose differ by a factor up to 5. The shift fromHp(10) toHpposes considerable challenges for its integration into existing personnel dosimetry systems. This is particularly relevant to the diagnostic radiology sector, where photon energies predominantly range between 20 and 100 keV and approximately 70% of monitored occupational workers are from this sector. In this context, the present study investigates the feasibility of implementing the updated OQs for multi-element passive dosimetry systems, such as CaSO4:Dy-based thermoluminescent dosimeters and outlines a systematic approach. Three approaches were demonstrated for the implementation ofHp: a linear equation-based method, a non-linear equation approach, and a multi-stage machine learning model. The results indicate that all methods achieved promising accuracy in dose estimation, with the machine-learning model exhibiting a slight advantage. Notably, approximately 99% of the estimated doses fell within ±30% of the actual delivered dose, underscoring the reliability of these approaches for practical application. The present study highlights the distinct advantage of multi-element passive dosimeters, demonstrating their capability to accommodateHpwithout necessitating significant design modifications. Through a systematic approach for estimatingHp, this study establishes the efficacy of multi-element passive dosimeters as a viable solution for the implementation of ICRU-95 OQs in personnel monitoring systems.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...

