Predictive value of extracellular volume fraction determined using enhanced computed tomography for pathological
Jian Liu1,2,3, Xunlan Zhang2,3, Rui Lv3
1Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Engineering Research Center of Text Computing & Cognitive Intelligence, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Ministry of Education, Guizhou University, No. 2708, Huaxi Avenue, Guiyang, 550025, Guizhou, China.
Objective:
To explore the potential of using the extracellular volume fraction (ECV), measured through enhanced computed tomography (CT), as a tool for determining the pathological grade of clear cell renal cell carcinoma (ccRCC).
Methods:
This retrospective study, approved by the institutional review board, included 65 patients (median age: 58.40 ± 10.84 years) who were diagnosed with ccRCC based on the nucleolar grading of the International Society of Urological Pathology (ISUP). All patients underwent preoperative abdominal enhanced CT between January 2022 and August 2024. CT features from the unenhanced, corticomedullary, nephrographic, and delayed phases were analyzed, and the extracellular volume fraction (ECV) of ccRCC was calculated by measuring CT values from regions of interest in both the unenhanced and nephrographic phases. Statistical significance was evaluated for differences in these parameters across the four ISUP grades. Additionally, diagnostic efficiency was assessed using receiver operating characteristic (ROC) curve analysis.
Results:
The ECV showed significant differences across the four ISUP grades of ccRCC, its potential as an important predictor of high-grade ccRCC (P = 0.035). The ROC curve analysis indicated that ECV exhibited the highest diagnostic efficacy for assessing the lower- and higher- pathological grade of ccRCC, with an area under the ROC curve of 0.976. The optimal diagnostic threshold for ECV was determined to be 41.64%, with a sensitivity of 91.31% and a specificity of 97.62%.
Conclusions:
ECV derived from enhanced CT has the potential to function as an in vivo biomarker for distinguishing between lower- and higher-grade ccRCC. This quantitative measure provides diagnostic value that extends beyond traditional qualitative CT features, offering a more precise and objective assessment of tumor grade.