Carotid Plaque-RADS: Inter- and Intrareader Agreement and Learning Curve Analysis in CTA
Luca Saba1, Roberta Scicolone2, Gian Luca Chabert2
1From the Department of Radiology (L.S., R. Scicolone, G.L.C., R.C.), Azienda Ospedaliero-Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Cagliari, Italy lucasaba@tiscali.it.
The Carotid Plaque-Reporting and Data System (RADS) shows substantial inter-reader agreement among experienced readers for assessing carotid atherosclerosis via computed tomography angiography (CTA). A learning curve exists for beginners, but consistency improves with experience, ensuring reproducible data.
Area of Science:
- Radiology
- Vascular Imaging
- Stroke Prevention
Background:
- Carotid artery stenosis is a primary cause of ischemic stroke.
- Plaque composition and morphology are crucial for stroke risk assessment.
- Carotid Plaque-Reporting and Data System (RADS) standardizes plaque evaluation beyond stenosis degree.
Purpose of the Study:
- To evaluate the inter-reader and intra-reader agreement of Carotid Plaque-RADS.
- To assess the learning curve associated with Carotid Plaque-RADS implementation.
- To establish the reliability of Carotid Plaque-RADS in routine radiological practice.
Main Methods:
- Retrospective analysis of 500 computed tomography angiography (CTA) exams for carotid atherosclerosis.
- Three readers with varying experience levels independently assessed carotid arteries using Carotid Plaque-RADS.
- Inter-reader and intra-reader agreement calculated using Cohen's kappa (κ) across multiple assessment blocks.
Main Results:
- Substantial agreement (κ=0.78-0.88) between expert and intermediate readers.
- Moderate agreement (κ=0.50-0.74) between intermediate and beginner readers.
- Significant improvement in expert-beginner agreement across blocks, indicating a learning curve.
- Near-perfect intra-reader agreement (κ=0.88) for intermediate and expert readers.
Conclusions:
- Carotid Plaque-RADS demonstrates substantial to near-perfect inter-reader agreement among experienced and intermediate readers.
- A learning curve is evident for beginners, with agreement improving over time.
- High intra-reader agreement ensures grading consistency and data reproducibility for Carotid Plaque-RADS.
More Related Videos
09:33A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...