Machine learning-assisted surface-enhanced raman spectroscopy for the rapid determination of the glutathione redox

Wilson A Garuba1, Brian A Barth2, Adam E Imel3

  • 1Department of Chemistry, University of Tennessee, Knoxville, TN 37996, USA. bhavya.sharma@utk.edu.

The Analyst
|April 8, 2025
PubMed

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Rapid Identification of Pathogens01:25

Rapid Identification of Pathogens

MALDI-TOF MS has transformed clinical microbiology by offering a rapid and reliable method for pathogen identification. The traditional approach to microbial identification typically involves time-consuming culture techniques and biochemical tests, which can delay the initiation of appropriate antimicrobial therapy. MALDI-TOF MS avoids these delays by using characteristic ribosomal protein mass patterns of microbial cells, enabling accurate species-level identification within minutes.Principle...