Related Experiment Video
Updated: May 15, 2025

Extraction and Characterization of Surfactants from Atmospheric Aerosols
Published on: April 21, 2017
Revolutionizing silver quantification: a novel ternary surfactant system with 2-nitro-6-(thiazol-2-yl-diazenyl)phenol
Muneera Alrasheedi1, Salah M El-Bahy2, Refat El-Sayed3,4
1Department of Chemistry, College of Science, Qassim University Buraidah 51452 Saudi Arabia.
Abstract:
Although modern reported methods, such as AAS, ICP-AES, ICP-MS, have good sensitivity, the high cost of equipment, the need for sophisticated instruments, separation and preconcentration steps and experienced technicians along with lack of precise methods make them cumbersome. Solid phase extraction (SPE) emerges as an attractive technique that reduces solvent consumption, minimizes exposure, shortens extraction time, and lowers disposal costs. Herein, a pioneering methodology for the quantification of minute amounts of silver is introduced, using 2-nitro-6-(thiazol-2-yl-diazenyl)phenol (NTDP) as a complexing agent and Triton X-100 as a nonionic surfactant within a ternary surfactant system at a pH of 5.3. This novel extraction strategy demonstrated selective preconcentration. The enriched solution was subjected to spectrophotometric analysis for the quantification of the analyte. After refining extraction and complexation parameters, a remarkable 250-fold increase in the enrichment factor was attained, highlighting a sensitivity boost of 509 times compared with traditional extraction approaches relying solely on nonionic surfactants. The key parameters of molar absorptivity and Sandell sensitivity were determined to be 6.04 × 106 L mol-1 cm-1 and 0.0018 ng cm-2, respectively. The calibration plot was observed from 5.0-175 ng mL-1, whereas Ringbom optimum concentrations ranged from 15-160 ng mL-1. The detection and quantification limits were 1.63 and 4.95 ng mL-1, respectively. The relative standard deviation (RSD) of the complex was 2.27. The suggested method was efficiently utilized for assessing the Ag+ concentration in real samples, producing acceptable outcomes.
Related Concept Videos
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Titration Curve: Analysis
Washing, Drying, and Ignition of Precipitates
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Titrimetric Methods: Types and Commonly Used Strategies