Related Experiment Video
Updated: May 15, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
A Method to estimate the economy-wide consequences of widespread, long duration electric power interruptions
Ian Sue Wing1, Peter H Larsen2, Juan Pablo Carvallo3
1Boston University, Boston, MA, USA.
Abstract:
We partnered with a utility in the U.S. state of Illinois to develop and pilot an approach to estimate the economic impacts of widespread, long duration (WLD) power interruptions. We surveyed their customers about hypothetical blackouts, identifying and classifying mitigating/resilience behaviors and quantifying their costs and benefits. Survey results are scaled up to the broader regional economy, and used to drive a computational general equilibrium (CGE) simulation of the effects of power interruptions and attendant customer responses (e.g., relocation, backup generation). Impacts are severe: 1-, 3-, and 14-day interruptions reduce the utility service area's three-month GDP by $1.8 Bn (1.3%), $3.7 Bn (2.6%) and $15.2 Bn (10.4%), respectively, with losses driven overwhelmingly by disequilibrium responses to shortages as opposed to price signals (71%-88%). Doubling backup power penetration moderates GDP losses by 11%-14%, and is relatively least beneficial during the longest interruption duration. Results highlight previously unquantified economic losses that can potentially be avoided by investments in power system resilience.
Related Concept Videos
Distribution Reliability and Automation
Power System Three-Phase Short Circuits
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Energy and Power Signals