Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

207
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
207
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

136
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
136
Electrogravimetric Analysis: Overview01:30

Electrogravimetric Analysis: Overview

164
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
164
Electrolysis03:00

Electrolysis

25.8K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
25.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Redirecting Excited-State Proton Transfer Through Supramolecular Polymerization in Nanoconfinement.

Angewandte Chemie (International ed. in English)·2026
Same author

Microfluidic compartmentalization reveals that ferrostatin-1 restores directional mitochondrial transport in Aβ-challenged neurons.

Lab on a chip·2026
Same author

Microfluidic NMR for <i>operando</i> monitoring of drug-induced metabolic fluxes in liver tissue slices.

Lab on a chip·2026
Same author

Internal reference for determining liquid crystal orientation at alignment layers in liquid crystal cells by confocal polarised Raman microscopy.

Physical chemistry chemical physics : PCCP·2026
Same author

Competition between Oxygen Atom Transfer from a Non-Heme N4-Coordinated Fe(IV) ═ O to Styrene and Water-Accelerated Comproportionation.

Inorganic chemistry·2026
Same author

Ligand driven heterolytic O-O bond cleavage in a non-haem phenolato-Fe(III)-OOH complex to yield a formal Fe(V)O intermediate.

Dalton transactions (Cambridge, England : 2003)·2025

Related Experiment Video

Updated: May 15, 2025

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
09:56

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example

Published on: November 18, 2015

9.6K

Electrochemical Flow Reactors: Mass Transport, iR Drop, and Membrane-Free Performance with In-Line Analysis.

W J Niels Klement1, Elia Savino1, Sarah Rooijmans1

  • 1Molecular Inorganic Chemistry, Stratingh Institute for Chemistry, Faculty of Science and Engineering, University of Groningen, Nijenborgh 3, 9474AG Groningen, The Netherlands.

ACS Electrochemistry
|April 9, 2025
PubMed
Summary
This summary is machine-generated.

This study introduces a microfluidic electrochemical device with large, parallel electrodes. This design minimizes potential loss and enhances mass transport for efficient electrochemical conversions.

More Related Videos

A Protocol for Electrochemical Evaluations and State of Charge Diagnostics of a Symmetric Organic Redox Flow Battery
09:49

A Protocol for Electrochemical Evaluations and State of Charge Diagnostics of a Symmetric Organic Redox Flow Battery

Published on: February 13, 2017

10.4K
Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions
08:41

Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions

Published on: September 7, 2018

8.8K

Related Experiment Videos

Last Updated: May 15, 2025

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
09:56

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example

Published on: November 18, 2015

9.6K
A Protocol for Electrochemical Evaluations and State of Charge Diagnostics of a Symmetric Organic Redox Flow Battery
09:49

A Protocol for Electrochemical Evaluations and State of Charge Diagnostics of a Symmetric Organic Redox Flow Battery

Published on: February 13, 2017

10.4K
Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions
08:41

Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions

Published on: September 7, 2018

8.8K

Area of Science:

  • Electrochemistry
  • Chemical Engineering
  • Microfluidics

Background:

  • Continuous flow reactors offer advantages for electrochemical conversions due to efficient reagent delivery.
  • Microfluidic reactors provide precise control over fluid dynamics, crucial for optimizing reaction efficiency.
  • Electrochemical conversion efficiency is governed by diffusion, electrode area, and potential drop (iR drop).

Purpose of the Study:

  • To develop a microfluidic electrochemical device with large, parallel electrodes.
  • To minimize iR drop and ensure a constant electrode potential along the electrode length.
  • To enhance mass transport rates for improved electrochemical conversion efficiency.

Main Methods:

  • Designed a microfluidic electrochemical device with parallel, large-area electrodes separated by laminar flow.
  • Incorporated herringbone grooves to induce transverse flow and enhance mass transport.
  • Utilized computational fluid dynamics (CFD) for flow behavior analysis.
  • Verified device performance using UV/vis absorption and resonance Raman spectroscopy.

Main Results:

  • The parallel electrode configuration successfully minimized iR drop, maintaining a constant electrode potential.
  • Herringbone grooves effectively increased mass transport rates.
  • CFD simulations and experimental results confirmed the predicted fluid flow behavior and enhanced mass transport.
  • The device design facilitates larger electrode areas and improved electrochemical efficiencies.

Conclusions:

  • The developed microfluidic electrochemical device enhances efficiency by minimizing iR drop and improving mass transport.
  • Separating electrodes via laminar flow instead of a membrane reduces cell resistance.
  • This approach is promising for the future development of high-efficiency electrochemical flow reactors.