Related Experiment Video
Updated: May 15, 2025

Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Development of an Inductively Coupled Plasma Atomic Emission Method for Determining Aluminium Levels in Animal
Novica Bojanić1, Jelena Mrmošanin2, Aleksandra Pavlović2
1Faculty of Medicine, Research Center for Biomedicine, University of Niš, Nis, Serbia.
Abstract:
In this study, an inductively coupled plasma-atomic emission spectroscopy method was developed to determine the Al in rats' tissue (liver, kidneys and testicles). The Mg II (280.270 nm)/Mg I (285.213 nm) ratio was used to achieve plasma robustness. The method was validated by detection and quantification limit, accuracy, precision, linearity and recovery. For the chosen analytical line of 308.215 nm, the correlation coefficient was 0.99998 in the checked interval. The limits of detection (0.067 µg/g) and quantification (0.225 µg/g), as a measure of the sensitivity of the method, were calculated. A total of 36 rats were treated with varying doses of AlCl3 for 8 weeks, after which their tissues were analysed. The results obtained showed that the Al accumulation decreased in the order liver > kidneys > testicles. Also, liver and testicle samples treated with verapamil show lower aluminium accumulation than samples treated with the same aluminium concentration without verapamil. The recoveries in spiked samples were between 91.8% and 108.4%. Multivariate methods were used to differentiate samples based on aluminium contents. The results of the research show the protective effect of verapamil in chronic aluminium exposure and could be important in further medicinal (therapeutic) studies.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...

