Radiofrequency-based wearable sensor patch in heart failure management: a focused review
Phuuwadith Wattanachayakul1,2, Veraprapas Kittipibul3,4, Marat Fudim5,6
1Department of Medicine, Jefferson Einstein Hospital, Philadelphia, PA, USA.
Abstract:
ZOLL Heart Failure Management System (ZOLL HFMS) is a non-invasive, remote monitoring device that employs radiofrequency signals transmitted through an adhesive patch embedded with integrated sensors to evaluate lung fluid levels. By analyzing trends in lung fluid status and related parameters, ZOLL HFMS may facilitate the early detection of heart failure (HF) decompensation and enable timely interventions. Insights from the recent BMAD trial (Impact of heart failure management using thoracic fluid monitoring from a novel wearable sensor: Results of the Benefits of Microcor [µCor™] in Ambulatory Heart Failure) highlight its promise in those with recent HF hospitalization, demonstrating a reduction in time to first HF readmission and improvement in quality of life. In this review, we summarize data on the ZOLL HFMS, with a focus on its lung fluid analysis mechanism for early HF decompensation detection and the accuracy of its measurements compared to other modalities. Then, we examine key outcomes from the recent BMAD trial, highlighting their clinical relevance and identifying gaps that warrant further investigation in future clinical trials. Lastly, we outline potential directions for integrating this technology into routine HF management.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Pathophysiology of Heart Failure