Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Evaluation of ion source parameters and liquid chromatography methods for plasma untargeted metabolomics using
Hailemariam Abrha Assress1, Ahsan Hameed1, Lindsay M Pack2
1Arkansas Children's Nutrition Center, Little Rock, AR, USA; Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
Abstract:
Although untargeted metabolomics holds promise for study of metabolites in human health and disease, robust method development and optimization are needed to reduce potential analytical biases and to ensure comprehensive, high-throughput results. In this study, the effect of mass spectrometer (MS) ion source parameters on the signal reproducibility and number of metabolite annotations during untargeted metabolomics is shown. Furthermore, different mobile phase gradients and columns (five reversed phase (RP)-C18 and two hydrophilic interaction liquid chromatography (HILIC) columns) were evaluated for untargeted metabolomics of blood plasma extracts. Positioning the electrospray needle at the farthest on the Z-direction and the closest tested position on the Y-direction with respect to the mass spectrometry inlet produced the best signal reproducibility and the greatest number of metabolite annotations. Moreover, optimal ion source conditions included a positive spray voltage between 2.5 and 3.5 kV, a negative spray voltage between 2.5 and 3.0 kV, vaporization and ion transfer tube (ITT) temperature between 250 and 350 °C, 30 to 50 arbitrary units of sheath gas, and at least 10 auxiliary gas units. Despite the differences in chromatographic characteristics, the different RP columns assessed showed comparable performance in terms of number of metabolites annotated. For HILIC columns, a zwitterionic column demonstrated better performance than an amide column. Finally, as compared with use of a RP column alone, use of both the optimal RP and HILIC approaches expanded metabolome coverage: the number of metabolites annotated increased by 60 %. This study highlights the significance of fine-tuning the MS ion source parameters and optimizing chromatographic conditions on metabolome coverage during untargeted metabolomics of plasma samples.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...