Exploring the limitations of blood pressure estimation using the photoplethysmography signal
Felipe M Dias1,2, Diego A C Cardenas1, Marcelo A F Toledo1
1Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil.
Abstract:
Objetive.Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) emerges as a promising approach for continuous BP monitoring. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, requiring a comprehensive evaluation of their efficacy. This paper aims to provide the potentials and limitations regarding BP estimation from single-site PPG signals.Approach.We developed a calibration-based Siamese ResNet model for BP estimation. We compared the use of normalized PPG (N-PPG) against the normalized invasive arterial BP (N-IABP) signals as input. N-IABP signals, while not directly presenting systolic (SBP) and diastolic (DBP) BP values, are expected to offer more precise estimations than PPG since it is a direct pressure sensor inside the body. Thus, if N-IABP poses challenges in BP estimation, predicting BP from PPG signals might be even more challenging.Main results.Our evaluation, conducted using the AAMI and BHS standards on the VitalDB dataset, revealed that inference using N-IABP signals meet with AAMI standards for both SBP and DBP, with errors of1.29±6.33mmHg for systolic pressure and1.17±5.78for diastolic pressure. In contrast, N-PPG based inference exhibited inferior performance than N-IABP, presenting1.49±11.82mmHg and0.89±7.27mmHg for systolic and diastolic pressure respectively in their best setup.Significance.Our findings establish a critical benchmark for PPG performance, providing realistic expectations for its BP estimation capabilities. We concluded that while PPG signals contain BP-correlated information, they may not suffice for accurate prediction.
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure