Related Experiment Video
Updated: May 15, 2025

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Correlation and consistency analysis between various indirect portal pressure gradients and actual portal pressure
Rufeng Chen1,2,3, Yaozu Liu1,2,3, Li Ma1,2,3
1Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.
Objective:
To evaluate the correlation and consistency between hepatic venous pressure gradient(F-HVPG) calculated as the wedged hepatic venous pressure (WHVP) minus free hepatic venous pressure (FHVP), I-HVPG calculated as WHVP minus inferior vena cava pressure (IVCP) in the hepatic segment, and portal pressure gradient (PPG).
Methods:
Data were collected from 112 patients with portal hypertension undergoing transjugular intrahepatic portosystemic shunt (TIPS) along with HVPG measurement. FHVP, IVCP, WHVP, and portal venous pressure (PVP) were collected intraoperatively. Pearson's correlation and Bland-Altman method were used to assess correlation and consistency.
Results:
A total of 112 patients were retrospectively collected. The correlation coefficient (r) values (p < 0.001) between FHVP and IVCP, WHVP and PVP, F-HVPG and I-HVPG, F-HVPG and PPG, I-HVPG and PPG were 0.835, 0.717, 0.946, 0.667 and 0.698, respectively; the determination coefficient (R2) values were 0.697, 0.514, 0.895, 0.445 and 0.487, respectively. Bland-Altman plots showed that F-HVPG and I-HVPG had the narrowest 95% limits of agreement. Among patients with FHVP-IVCP > 2 mmHg, the (r) values (p < 0.05) between F-HVPG and I-HVPG, F-HVPG and PPG, I-HVPG and PPG were 0.907, 0.648 and 0.807, respectively; the (R2) values were 0.822, 0.420 and 0.651, respectively. Bland-Altman plots showed that I-HVPG had the narrower 95% limits of agreement with PPG.
Conclusion:
F-HVPG and I-HVPG demonstrated high correlation and consistency. I-HVPG consistently correlates more closely with PPG than F-HVPG, both in the overall cohort and in patients with FHVP-IVCP > 2 mmHg. These results suggest that I-HVPG may serve as a more reliable alternative. Due to the significant underestimation of the PPG, HVPG measurement should not be used to exclude patients from a TIPS intervention.
More Related Videos
09:37Invasive Hemodynamic Characterization of the Portal-hypertensive Syndrome in Cirrhotic Rats
Published on: August 1, 2018
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Fluid Pressure over Curved Plate of Constant Width
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines.
Static, Stagnation, Dynamic and Total Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement