Related Experiment Video
Updated: May 15, 2025

An “All-laser” Endothelial Transplant
Published on: July 6, 2015
Femtosecond laser-assisted intracorneal MyoRing explantation - A novel rescue technique
Nikolaus Luft1, Stefan Kassumeh1, Martin Dirisamer1
1Department of Ophthalmology, LMU University Hospital, LMU Munich, Mathildenstrasse 8, Munich, Germany.
Purpose:
We describe a case of a keratoconus patient with decreased uncorrected visual acuity after MyoRing implantation, where explantation was indicated.
Observations:
A 25-year-old male patient was referred to our institution for evaluation after being deemed unfit for service as a police officer for six months. He had received a MyoRing ring implant in his right eye due to keratoconus. Following the procedure, he experienced decreased uncorrected visual acuity, intolerance to contact lenses, and unsatisfactory visual acuity with glasses. Consequently, a femtosecond laser-assisted removal of the ring implant was performed.
Conclusions And Importance:
We present a novel femtosecond laser-based "rescue" technique for the removal of continuous corneal ring implants that cannot be extracted via the original intrastromal pocket. The minimal-invasive FS-approach might also be useful for the explantation of other intracorneal implants (e.g. ICRS) or devices that cannot be removed via the original surgical approach.