Related Experiment Video
Updated: May 8, 2025

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025
Poster Session: Contrast polarity in photopic, mesopic, and scotopic vision
Lisa Widmayer1, Alexander C Schütz1
1University of Marburg.
Abstract:
The perception of dark and light shows considerable asymmetries. In scotopic vision, "white" patches appear gray - brightness perception is clipped at the upper end of the range. In photopic vision, darks are perceived as relatively more intense than lights. Here, we compared perception of contrast polarities in photopic, mesopic, and scotopic viewing. We tested the perception of positive and negative contrasts in the three viewing conditions, using a circular stimulus (2° radius) presented for 200 ms at 8° eccentricity. In a detection task, we obtained absolute thresholds for positive and negative contrasts. In a matching task, we obtained PSEs when participants compared stimuli with positive and negative contrasts at three contrast levels (0.2, 0.35, 0.5). Stimuli were defined in Weber's contrast. In the detection task, thresholds were highest in scotopic and lowest in photopic vision. Thresholds were higher for positive than negative contrasts in mesopic and scotopic but not in photopic viewing. In the matching task, the asymmetry was increased in scotopic compared to photopic viewing, such that even more positive contrast was required to match negative contrasts. Our results show that the asymmetry in contrast perception depends on the lighting condition, being largest in scotopic vision in both tasks. As signals from cone receptors are crucial for perceiving "white", the clipped range in scotopic vision also seems to impede the perception of positive contrasts.
More Related Videos
Related Concept Videos
Photoreceptors and Visual Pathways
Color Vision
Anatomy of the Eyeball
Vision
The Retina
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

