Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Smartwatch-Derived VO2max Prediction Model for Korean Adults: Utilizing Heart Rate and GPS Data from the 12-Minute
Kihyuk Lee1, Dohee Kim2, Sungeun Shin2
1Data Convergence Team, Seoul National University Bundang Hospital, Seongnam 13605, Republic of Korea.
Abstract:
Background/Objectives: Recent technological advancements enable smartwatches to measure running distance and heart rate using wearable sensors. This study aimed to analyze the validity of the 12 min Cooper test using a smartwatch and to develop an accurate VO2max prediction model for Korean adults. Methods: A total of 104 adults (53 males: age 35.00 ± 6.1 years, BMI 24.71 ± 3.13; 51 females: age 34.82 ± 6.07 years, BMI 22.24 ± 2.66) participated. VO2max was measured using a maximal graded treadmill test. Participants performed the Cooper test while wearing a smartwatch, which collected average heart rate, peak heart rate, and running distance. Sex, height, and weight were also included as predictor variables. Multiple regression analysis was conducted to develop a VO2max prediction equation. Model accuracy was assessed using R2 and the standard error of the estimate (SEE). Results: The developed VO2max prediction equation was VO2max = 27.620 + 6.358 (sex; male = 1, female = 0) - 0.012 (height) - 0.202 (weight) - 0.036 (mean HR) + 0.039 (peak HR) + 0.012 (distance) (R2 = 0.853, SEE = 3.176 mL/kg/min, p < 0.001). The intra-class correlation coefficient (ICC) between measured and predicted VO2max using the smartwatch was 0.961, compared to 0.925 for traditional methods. The explanatory power was 86.0% (SEE = 3.024 mL/kg/min) versus 81.0% (SEE = 3.516 mL/kg/min). Conclusions: The smartwatch-based VO2max prediction model demonstrated higher accuracy than traditional methods. This equation is recommended for more precise VO2max estimation in Korean adults.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...