Infrared thermography of beef carcasses and random forest algorithm to predict temperature and pH of Longissimus
Aline Rabello Conceição1, Nathália Farias de Souza1, Amanda Candian Coeli1
1Department of Animal Science, Federal University of Viçosa, Viçosa, Minas Gerais 36570-900, Brazil.
Abstract:
This study aimed to evaluate the use of infrared thermography (IRT) as a method for predicting the initial and ultimate temperature, as well as the pH, of the Longissimus thoracis in beef carcasses (LTBC). A total of 102 beef carcasses, consisting of 62 F1 Red Angus × Nelore and 40 Nelore cattle, approximately 14 months of age, were evaluated before and after refrigeration. Temperature and pH values of the LTBC were measured using a probe thermometer and a pH meter. To predict these parameters, IRT was used to measure surface temperature features of the fore, hind, and Longissimus thoracis regions, as well as the whole carcass. The Random Forest machine learning algorithm was applied for predictive modeling. The results of this study indicated that it was possible to use IRT to predict temperature of LTBC with R2 values ranging from 0.06 to 0.78 and MAE from 1.12 to 1.67. For initial temperature was R2 of 0.06 and ultimate temperature with R2 values 0.26 and 0.17. The inclusion of hot carcass weight (HCW) parameter improved the prediction of ultimate temperature with an R2 from 0.78 to 0.86. The prediction of LTBC pH with thermal images showed R2 values ranging from 0.26 to 0.82 and MAE from 0.10 to 0.82. The combination of IRT and HCW improved the prediction of muscle ultimate pH in the carcass. In conclusion, the IRT method can predict the initial and ultimate pH and temperature of LTBC, with improved accuracy when combined with the HCW parameter.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...