Purpose:
Removal of volar locking plates after healing of a distal radius fracture is becoming increasingly common. However, it is unclear how the fracture healing proceeds and which defects remain. The aim of this study was to assess changes in bone microarchitecture and biomechanical properties in surgically treated radius fracture after volar locking plate removal.
Methods:
Twelve patients were recruited after undergoing plate removal. High Resolution Quantitative Computed Tomography (HR-pQCT) was used to perform scans of the fractured and contralateral distal radius on average one (M1) and 16 months (M2) after plate removal. Parameters measured were cortical- (Dcomp), trabecular- (Dtrab) and total bone density (D100), as well as cortical thickness (Ct.Th). Axial bone stiffness (FE.Kaxial) was determined through linear micro-finite element analysis (µFEA).
Results:
At M1, no significant differences between fractured and contralateral side were detected except for Dcomp. At the fractured side, all parameters except for Dtrab increased significantly between M1 and M2. At M2, Ct.Th and FE.Kaxial were significantly higher at the fractured side compared to the contralateral side, but Dcomp remained significantly lower. Qualitatively, closure of the screw holes was observed between M1 and M2, while large trabecular defects remained.
Conclusion:
Bone (re)modeling at the distal radius is an ongoing process even after plate removal and leads to a partial exaggeration of the bone properties relative to the intact contralateral side. It seems that the bone regains its biomechanical competence by closing screw holes and increasing cortical thickness, which compensates for trabecular defects that cannot be repaired.
Level Of Evidence:
III.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Bone Remodeling
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Osteoclasts in Bone Remodeling
Bone Structure