Objectives:
Monoclonal gammopathies (MGs) are characterized by the presence of monoclonal immunoglobulins (M-proteins). Currently, recommendations for screening of MGs primarily rely on nephelometry, turbidimetry and electrophoresis, which have inherent limitations in sensitivity and throughput. This study aimed to evaluate a novel MALDI-TOF MS-based method, the intact M-protein Screening-Light Chain Assay (iMS-LC Assay), for direct M-protein detection and quantification without antibody enrichment.
Methods:
Residual serum samples previously analyzed via serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) were reduced to dissociate light chains from heavy chains. MALDI-TOF MS was then performed to determine the presence of M-protein characteristic pattern. The iMS-LC Assay's analytical sensitivity, specificity, and screening efficacy in healthy populations were assessed.
Results:
The iMS-LC Assay successfully detected all M-proteins identified by SPE and demonstrated higher sensitivity in analytical and diagnostic studies. It accurately quantified M-proteins at concentrations below 10 g/L, with a detection limit of 0.2 g/L and the ability to detect levels below 0.1 g/L. For samples with M-protein concentrations >1 g/L, intra-assay and inter-assay coefficients of variation were <10 %. In prospective screening of M-proteins in the healthy population, the iMS-LC Assay detected M-proteins at a prevalence of 3.15 %, higher than IFE (1.87 %) and SPE (0.94 %).
Conclusions:
The iMS-LC Assay shows potential to replace SPE and drive advancements in the screening, diagnosis, and monitoring of MGs. Further validation of its clinical sensitivity and specificity is essential to determine its adequacy as a routine screening tool for M-proteins.
More Related Videos
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
13:00Low Molecular Weight Protein Enrichment on Mesoporous Silica Thin Films for Biomarker Discovery
Published on: April 17, 2012
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...