Related Experiment Video
Updated: May 11, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Development, validation and applications of a GC/MS method for the simultaneous determination of 9 amphetamines and
Christoforos Bouzoukas1, Panagiota Nikolaou2, Sotirios Athanaselis2
1Department of Forensic Medicine and Toxicology, School of Medicine, National and Kapodistrian University of Athens, Greece; Division of Pharmaceutical Analysis, Faculty of Pharmacy, National and Kapodistrian University of Athens, Greece.
Abstract:
Amphetamine-type stimulants (ATS), synthetic cathinones (SCs) and phenethylamines (PEAs) pose a challenge to toxicology laboratories. Their extensive use and misuse has led to an increase of intoxications and fatal incidents worldwide. So, the need for new analytical methods for their determination in biological samples is crucial for all toxicology laboratories for a better investigation of these cases. The aim of this study was the development and validation of an analytical method for the determination of 9 ATS, 7 SCs and 5 PEAs in whole blood and urine using gas chromatography coupled with mass spectrometry. The samples were pretreated by solid-phase extraction and derivatized with pentafluoropropionic anhydride. Chromatographic separation of the 21 analytes was achieved in less than 11 min. The method was validated according to international guidelines for selectivity, specificity, linearity, limits of detection (LODs) and quantification (LOQs), precision, accuracy and recovery of the method. The LODs of the analytes ranged from 0.70 to 7.0 ng/mL and the values of the LOQs ranged from 2.0 to 20 ng/mL. The linearity of the 21 analytes, according to the group of substances, were 2.0 ng/mL - 0.20 μg/mL, 5.0 ng/mL - 0.50 μg/mL, 10 ng/mL - 0.50 μg/mL and 20 ng/mL - 0.50 μg/mL with R2 values > 0.99. Extraction recoveries were > 80 % for all analytes. Intra and inter day accuracy and precision of the method were within accepted limits. The developed method was applied to post-mortem blood and urine samples of 46 forensic cases sent for toxicological investigation to the Department of Forensic Medicine and Toxicology, School of Medicine, National and Kapodistrian University of Athens. The results of the analyses revealed the presence of methamphetamine, amphetamine, MDMA, MDA, pseudoephedrine, phenylpropanolamine or MBDB in 14 cases.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors