Related Experiment Video
Updated: May 1, 2026

07:50
Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
10.8K
A Tutorial for Scanning Electrochemical Cell Microscopy (SECCM) Measurements: Step-by-Step Instructions, Visual
Kamsy Lerae Anderson1, Martin Andrew Edwards1
1Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States.
ACS Measurement Science Au
|April 21, 2025
Summary
This guide simplifies nanoscale electrochemical mapping using Scanning Electrochemical Cell Microscopy (SECCM). It provides a step-by-step approach, troubleshooting, and data to help beginners master this powerful surface characterization technique.
Area of Science:
- Electrochemistry
- Surface Science
- Nanotechnology
Background:
- Scanning Electrochemical Cell Microscopy (SECCM) enables nanoscale electrochemical mapping of surfaces.
- SECCM utilizes a nanopipette meniscus as a mobile electrochemical cell.
- Despite its growing applications, SECCM can be challenging for new users.
Purpose of the Study:
- To provide a comprehensive, step-by-step guide for performing initial SECCM experiments.
- To demystify SECCM for researchers lacking direct expert access.
- To serve as an entry point for understanding and utilizing SECCM.
Main Methods:
- Detailed experimental procedures for SECCM.
- Inclusion of troubleshooting strategies and common problem identification.
- Provision of suggested parameters, experimental systems, and representative data.
Main Results:
- A clear, accessible pathway to conducting SECCM experiments is established.
- Fundamentals of SECCM are explained with experimental rationale.
- The guide equips users with the knowledge to overcome common experimental hurdles.
Conclusions:
- This work significantly lowers the barrier to entry for SECCM adoption.
- It empowers researchers to independently perform nanoscale electrochemical characterization.
- The guide fosters broader utilization of SECCM in scientific research.
More Related Videos
Related Concept Videos
Scanning Electron Microscopy
4.0K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.0K
Preparation of Samples for Electron Microscopy
5.3K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.3K