Double-beam flying spot scanner for two-dimensional polyacrylamide gel electrophoresis
Abstract:
The construction of a double-beam photometer in which the light source is a cathode ray oscilloscope is described. The light spot from the oscilloscope was focused and reduced in size at the gel plane to give a diameter of less than 0.15 mm and make it possible to scan over a 50 X 59-mm rectangle; using reduced spatial resolution (spot less than 0.2 mm) the area scanned becomes 70 X 90 mm. The light from the CRT was divided into two beams; one was directed through the transparent object to a photomultiplier and the other to a reference photomultiplier. The signals from these two detectors were converted to the logarithm of the ratio by a logging amplifier to give a direct measure of absorbance. Positioning of the spot, control of light intensity, and measurement of absorbance were carried out through an interface to a 16-bit computer. The relationship between measured and actual absorbance was linear over the range of absorbance 0 to 2, which could be raised to 1 to 3 by placing a neutral filter in the reference beam. The system generated an image containing 256 X 256 pixels in about 5 min, the scanning speed was determined by the persistence time of the P4 phosphor on the cathode ray tube, and faster scans can be made using A6 phosphor.
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation